WorldBond Piezo-Electric Corp.
About Products Inquiry Contact US Home


Product Categories

Surface Acoustic Wave (SAW)
Ceramic Components

Custom Ceramic Design

Dielectric Resonators & Filters
Quartz Crystal



Home >> Products >> Specification for Ceramic Filter
Specification for Ceramic Filter

Type: LTL310A

  1. Scope - This specification shall cover the characteristics of the ceramic filter with LTL310A.
  2. Mode Name - 2-1 Part No: LTL310A. 2-2 Specification No:
  3. Outline Drawing and Dimensions - 3-1 Appearance : No visible damage and dirt. 3-2 Dimensions : See Figure 1. 3-3 Construction : Use metal case for outside and seal up with epoxy resins.
  4. Ratings and Characteristics

     

    Item

    Requirements

    4-1

    Center Frequency

    310±1.0 KHz

    4-2

    Band Width (-6dB)

    3.55.5 KHz

    4-3

    Band Width (-60dB)

    8.0 KHz max.

    4-4

    Attenuation (310±100KHz)

    60.0 dB min.

    4-5

    Spurious Response  Range:0.6 to 6.0 MHz

    40 dB min.

    4-6

    Ripple

    3.0 dB max.

    4-7

    Insertion Loss

    6.0 dB max.

    4-8

    Insulation Resistance

    500 MΩ min.

    4-9

    Input / Output Impedance

     

     

     

    1.8 KΩ

    4-10

    Temperature Characteristics of

    Fo : ±50ppm/℃

    (from initial value)

     

    Center Frequency (-40℃ to +60℃)

    Operating Temperature

    -40℃ to +60℃

    Storage Temperature

    -45℃ to +65℃


    Note: Center frequency shall be defined as the central value of the band at -6 dB.

  5. Explanation Of Mechanical Strength Test And Environmental Test

     

     Testing Item

    Condition of Test

    Performance Requirements

    1

     Resistance to impact

     Drop the filter randomly onto a concrete floor the height of 30cm 3 times.

     No visible damage and the measured values shall meet Table 1.

    2

     Resistance to vibration

     Subject the filter to the vibration for 1 hour each in the X. Y. and Z. Axes with the amplitude of 1.5mm,the frequency of 10-55Hz.

     No visible damage and the measured values shall meet Table 1.

    3

     Firmness of lead

    Applied to vertical weight 1Kg along with the direction of lead without any shock for 5-10 sec.

     

     No evidence of harm should show.

    4

     Solder ability

     Dip the filter terminals no closer than 1.5mm into the solder bath at 230±5℃ for 5±1 sec.

     More than 95% of the terminal surface of the filter shall be covered with fresh solder.

    5

     Resistance to soldering heat

     Dip the filter terminals no closer than 1.5mm into the solder bath at 350±10℃ for 3 sec. Then release it into the room condition for 24 hours.

     

     The measured values shall meet Table 1.

    6

     Resistance to moisture

     Keep the filter at RH90%95% and 40±2℃ for 100 hours. Then release the filter into the room condition for 24 hours.

     

     The measured values shall meet Table 1.

    7

     High temperature storage

     Subject the filter to 85±2℃ for 100 hours. Then release the filter into the room condition for 24 hours.

     The measured values shall meet Table 1.

    8

     Low temperature storage

     Subject the filter to –55±2℃ for 100 hours. Then release the filter into the room condition for 24 hours.

     The measured values shall meet Table 1.

    9

     Temperature cycling

     Subject the filter to a low temperature of –55℃ for 30 min. Followed by a high temperature of 85℃ for 30 min. Cycling shall be repeated 5 times with a transfer time 15min.at the room temperature. Then release the filter into the room condition for 24 hours.

     

     The measured values shall meet Table 1.


  6. Measurement - 6-1 Test Circuit : See Figure 2. 6-2 Measuring Condition : Temperature 15~35?. Humidity 45%~75% R.H. If require : Temperature 25?±1?. Humidity 48%~52% R.H.

    Item

    Requirements

    Center Frequency Shift

    ±1.5 KHz max.(initial value)

    Frequency Shift(-3dB)

    ±1.0 KHz max.(initial value)

    Ripple Shift

    3.0 dB max.

    Insertion Loss

    6.0 dB max.


  7. Points For Attention - 7-1 Ceramic filter should be stored in storeroom. And the surrounding atmosphere is acidless, alkali-free and no other harmful impurity. 7-2 The package for ceramic filter should be avoided the hit by rain and snow, also the mechanical damage. 7-3 If the users are doubtful about the directions or have other special requests, please contact with us.





Home | Why WorldBond? | Inquiry | Products | Contact Us